CE/ISO Approved High Quality Hospital Anesthesia Ventilator Device Cwm-302

Product Details
Customization: Available
Gas Source: Oxygen, N2o, Air
Working Type: Electronic Control, Pneumatic Driven
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
114
Year of Establishment
2001-04-12
  • CE/ISO Approved High Quality Hospital Anesthesia Ventilator Device Cwm-302
  • CE/ISO Approved High Quality Hospital Anesthesia Ventilator Device Cwm-302
Find Similar Products

Basic Info.

Model NO.
CWM-302
Transport Package
Standard Export Packing
Specification
ISO, CE
Trademark
CW
Origin
China
HS Code
90189070
Production Capacity
5000PCS/Year

Product Description

Anaesthesia Machine (CWM-302):

12.1inch touch screen.
Applied for adult, pediatric and infants.
Compact anesthesia ventilation system.
Apply quick automatic compensation function for VT.
Easy to operate, user friendly for inhalation anesthesia.
Real-time detection for loops, Paw, BPM, VT and compliance.
Ventilation modes: VCV, PCV, PSV, SIMV-V, SIMV-P, A/C.
Breathing loops with zoom in/ out, freeze and comparison. 72 hrs trends records with 3000 logs.

Main specification:

Power: AC 220V ± 10%, 50Hz ± 2%, built-in battery for backup
Tital Volume range: 20-1500ml
I:E range: 4:1-1:8
Gas: O2 , N2O, air
Pipeline input range: 280-600kPa
Run-time: >=180min
Oxygen flush: 25 to 75L/minute
Flow meter: 5 tubes, Cascade 0.1-15L/min O2, 0.1-15L/min N2O, 0.1-15L/min air.
Vaporizers: 2 selectetac, maximum 2 mounts(Isoflurane/ Enflurane/ Sevoflurane/ Halothane)

Parameters monitoring: Tidal volume, minute volume, frequency, airway pressure, O² Concentration, lung compliance (optional)
Display graphics: Waveforms of P-T, F-T, V-T, loops of P-V, V-F, F-P (Zoom in/out, comparison, freeze)
Types: VT, MV, BPM, Paw, Lung compliance, Inspiratory Platform, FiO2
Alarm: No tital volume, MV, Paw, FiO2 limitation O2
 , Air faliture, AC power faliture, Battery low.
Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.


 
Operating Panel:   English (Standard)
 Drive:  Gas driven
 Application:   Applied for child and adult.
 Gas source:  Oxygen, N2O,Air
 Tidal volume:  20-1500ml
 Vaporizer:  Enflurane, Isoflurane, Halothane, Sevoflurane
 Concentration:    0~5% (0~8% for sevoflurane)
 Flow meter:    Four tubes 0.1~15L/min (with interlock hypoxic guard ensuring the oxygen concentration>21%)
 APL valve:   <6kpa
 Gas supply:   O /N O 0.28Mpa~0.6Mpa 
 O2 flush:   25~75L/min

Send your message to this supplier