Cost Effective High Quality Medical Patient Monitor Beta 12

Product Details
Customization: Available
Type: Patient Monitor
Kind: Patient Monitor
Still deciding? Get samples of US$ 600/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
114
Year of Establishment
2001-04-12
  • Cost Effective High Quality Medical Patient Monitor Beta 12
  • Cost Effective High Quality Medical Patient Monitor Beta 12
  • Cost Effective High Quality Medical Patient Monitor Beta 12
  • Cost Effective High Quality Medical Patient Monitor Beta 12
  • Cost Effective High Quality Medical Patient Monitor Beta 12
  • Cost Effective High Quality Medical Patient Monitor Beta 12
Find Similar Products

Basic Info.

Model NO.
Beta 12
Certification
ISO13485
Group
Children
LCD Display
With LCD Display
Screen Size
12.1 Inch TFT Screen
Parameter
12.1 Inch TFT Screen
Display
Maximum 6 Waves
Trend
Maximum 168 Hours
Specification
420*290*450mm GW: 7kg
Trademark
CHENWEI
Origin
China
HS Code
9018907010
Production Capacity
50000PCS/Year

Product Description

Cost Effective High Quality Medical Patient Monitor Beta 12Patient Monitor Beta 12
Cost Effective High Quality Medical Patient Monitor Beta 12

Feature


12.1 inch TFT screen, 6 standard parameters
32-levels sound volume adjustment
10-levels brightness adjustment
Maximum 168 hours graphic and tabular trends of all parameters Battery capacity about 5 hours continual working time

Maximum 20 hours continual working time (optional)
Touch screen (optional)
SPO2 module (optional)
EtCO2 module (optional)


Cost Effective High Quality Medical Patient Monitor Beta 12

TECHNICAL SPECIFICATION

1.  Patient  monitor  type
Standard electric shock proof: Class I electric shock proof equipment
EMC: Class A
Standard electric shock proof level:ECG (RESP): CF type; SpOz, NIBPATEMP: BF type
Liquid-proof level: Generally sealed equipment without liquid-proof function
Disinfection/sterilization method: Refer to Chapter Five for detailed information
Working method: Continuous

2.  Patient  monitor  specification

2.1 Working environment
Temperature range: Working: 0-40°ºC
Transportation  and  store:-20~60ºC
Humidity  range:  Working:≤85%
Transportation and store:≤93%(No dew condensation)
Altitude range:Working:-500 - 4,600m(- 1,600 - 15,000 feet)
Transportation   and   srore:-500- 13,100m(- 1,600-43,000   feet)
Electric specification:AC 100 240V,50/60Hz, max. 70VA of input power
Fuse is T 3. 15A display specification

2.2  Displayed  information
Max. 6 waves
One alarm indicator (Yellow/Red)
One working indicator (Green)
One battery charging state indicator (Yellow)
Three audible alarm modes corresponding to alarm states

2.3   Retrospection
Trend  retrospection
Short trend'1 hour, resolution:  1 second or 5 seconds
Long trend 72 hours, resolution: 1 minute, 5 minute or 10 minutes
NIBP measurement retrospection Retrospection on 400 NIBP measured data

3.   ECG  Specification

3.1  Lead  configuration
Standard 3-lead or 5-lead
3-lead    RA , LA , LL,Lead    method:    I,II,III
5-lead    RA ,LA ,LL ,RL ,V,Lead    method:    I,II,III,aVR,aVL,    aVF,    V

3.2   Increase
0.25,0.5,1,2,AUTO

3.3   HR
Range
Adult:  15~300bpm  (beat/minute)
Neonatal baby/children:  15~ 350 bpm (beat/minute)
Precision:±1%  or±1   bpm,the   larger   prevails
Resolution:   1   bpm(beat/minute)

3.4  Sensitivity:>200μV  (Peak-to-peak  value)

3.5  Input  Impedance:>5 (megohm)

3.6           Bandwidth
Diagnostic  mode:   0.05~130Hz
Monitoring   mode:  0.5~40Hz
Operation   mode:   1~20Hz

3.7 Common Mode rejection Ratio
Diagnostic   mode:>90   dB
Monitoring  mode:>  100  dB
Operation  mode:>100  dB

3.8 Pole Polarization Voltage Range:300mv

3.9  Pacing  Pulse Test
Test pacing pulse in acc ordance with the following conditions:
Amplitude:±2     mV~±700mV
Width:    0.1ms~2ms
Risetime:10μs~100μs

3.10  Pacing  Pulse  Inhibition
When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation.
Amplitude:±2    mV~±700mV
Width:  0.1ms~2ms
Risetime:10μs~100μs


Cost Effective High Quality Medical Patient Monitor Beta 12Cost Effective High Quality Medical Patient Monitor Beta 12

Cost Effective High Quality Medical Patient Monitor Beta 12











 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier