Ventilator Specifications
Modes of Ventilation |
|
VCV |
Volume Control Ventilation |
SIMV-V |
Synchronized Intermittent Mandatory Ventilation-Volume |
SIMV-P |
Synchronized Intermittent Mandatory Ventilation-Pressure |
MANUAL |
Manual |
A/C |
Assist/Control |
PCV |
Pressure Control Ventilation |
PSV |
Pressure Support Ventilation |
STAND-BY |
STAND-BY |
PA -VC (optional) |
Pressure-regulated Volume Control |
Ventilator Parameter |
|
Working type |
Electronic control, pneumatic driven |
Tidal Volume range |
10-1500ml |
Pressure range |
5-60 cmHz0 |
Rispriation rate range |
1-100 bpm (1-40bpm under SIMV) |
l:E range |
4:1-1:8 |
Ptrigger range |
-20-20 cmH20 (based on PEEP) |
Flow trigger |
0-15L |
Minute volume range |
>18 U/Min |
SIGH range |
0-5/100 |
System Standard |
|
Hypoxic guard system |
N2O cut-off valve, O2 concentration >25% |
Safety valve |
<12.5kPa |
Fresh gas compensation |
25-75L/min |
Volume of CO2 absorber |
2L |
Flow meter |
E-flowmeter (0.1-15L/min O2,0.1-15L/min N2O, 01-15L/min air) |
Vaporizer |
2 Selectetac, maximum 2 mounts (lsoflurane/Enflurane/Sevoflurane/Halothane) |
Monitoring |
|
Display graphics |
Waveforms of P-T, F-T, V-T, loops of P-VV-F,F-P(Zoom in/out,comparison,freeze) |
Types |
VT, minute volume range, airway pressure, I:E range, lung compliance |
|
plateau, O2 concentrationCO2 (optional).Anaesthetic Gas(optional) |
Alarm Limits |
|
Audio/Visual |
No tidal volume, MV,Paw, FiO2 limitation O2, Air failure, AC power failure, Battery low |
PEEP |
|
Type |
Integrated, Electronic control |
Range |
OFF,3-30cmH2O |
Auxiliary features |
|
ACGO |
Auxiliary Common Gas Outlet |
Yoke system(Pin-index) |
Support 11L cylinder,O2/N2O |
AGSS |
Anaesthetic Gas Scavenging Syetems(optional) |
Communication Interface |
Ethernet,USB,HDMI |
Worktable |
Optional |
Patient Monitor |
Optional |
E-anesthesia record |
Optional |
Auxiliary Oxygen meter |
Optional |
Physical Specifications |
|
Dimensions |
70*85*140cm |
Casters |
Front wheels with lock |
Screen |
15 inch LCD touchable |
Working Specifications |
|
Power |
AC 100V-240V.50Hz+2% |
Pipeline Supply |
|
Gas configuration |
O2,N2O,Air |
Pipeline input range |
280-600kPa |
Battery Power |
|
Run-time |
Up to 2 hrs |
Pre-setting Functions |
|
Language |
English |
Calibration |
Automatic |
Applications |
|
Patient range |
Audlt/ Pediatric/ Neonatal |
Extraordinary performance points
*15 inch colour touchable LCD screen, NO dead space in the screen
*E-flowmeter control with hypoxic guard
*Heated breathing circuit ensure no water trap in the system
*Internal inspiration and aspiration flow sensor
*Back-up cylinder system (Yoke system)
*3 gas sources support
*Compact Anesthesia ventilation system with the standard of ISO 9001: 13485
*Easy to operate, user friendly
*Ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring
*Support adult and pediatric
*Applied for closed, semi-closed, semi open inhalation anesthesia controlled or assisted ventilation
*CE approved
Specifications & Details