Customization: | Available |
---|---|
Type: | Anaesthesia Machine |
Kind: | Anesthesia Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Modes of Ventilation | |
VCV | Volume Control Ventilation |
SIMV-V | Synchronized Intermittent Mandatory Ventilation-Volume |
SIMV-P | Synchronized Intermittent Mandatory Ventilation-Pressure |
MANUAL | Manual |
A/C | Assist/Control |
PCV | Pressure Control Ventilation |
PSV | Pressure Support Ventilation |
STAND-BY | STAND-BY |
PA -VC (optional) | Pressure-regulated Volume Control |
Ventilator Parameter | |
Working type | Electronic control, pneumatic driven |
Tidal Volume range | 10-1500ml |
Pressure range | 5-60 cmHz0 |
Rispriation rate range | 1-100 bpm (1-40bpm under SIMV) |
l:E range | 4:1-1:8 |
Ptrigger range | -20-20 cmH20 (based on PEEP) |
Flow trigger | 0-15L |
Minute volume range | >18 U/Min |
SIGH range | 0-5/100 |
System Standard | |
Hypoxic guard system | N2O cut-off valve, O2 concentration >25% |
Safety valve | <12.5kPa |
Fresh gas compensation | 25-75L/min |
Volume of CO2 absorber | 2L |
Flow meter | E-flowmeter (0.1-15L/min O2,0.1-15L/min N2O, 01-15L/min air) |
Vaporizer | 2 Selectetac, maximum 2 mounts (lsoflurane/Enflurane/Sevoflurane/Halothane) |
Monitoring | |
Display graphics | Waveforms of P-T, F-T, V-T, loops of P-VV-F,F-P(Zoom in/out,comparison,freeze) |
Types | VT, minute volume range, airway pressure, I:E range, lung compliance |
plateau, O2 concentrationCO2 (optional).Anaesthetic Gas(optional) | |
Alarm Limits | |
Audio/Visual | No tidal volume, MV,Paw, FiO2 limitation O2, Air failure, AC power failure, Battery low |
PEEP | |
Type | Integrated, Electronic control |
Range | OFF,3-30cmH2O |
Auxiliary features | |
ACGO | Auxiliary Common Gas Outlet |
Yoke system(Pin-index) | Support 11L cylinder,O2/N2O |
AGSS | Anaesthetic Gas Scavenging Syetems(optional) |
Communication Interface | Ethernet,USB,HDMI |
Worktable | Optional |
Patient Monitor | Optional |
E-anesthesia record | Optional |
Auxiliary Oxygen meter | Optional |
Physical Specifications | |
Dimensions | 70*85*140cm |
Casters | Front wheels with lock |
Screen | 15 inch LCD touchable |
Working Specifications | |
Power | AC 100V-240V.50Hz+2% |
Pipeline Supply | |
Gas configuration | O2,N2O,Air |
Pipeline input range | 280-600kPa |
Battery Power | |
Run-time | Up to 2 hrs |
Pre-setting Functions | |
Language | English |
Calibration | Automatic |
Applications | |
Patient range | Audlt/ Pediatric/ Neonatal |